Related Experiment Video
Updated: May 21, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Direct extraction of urinary analytes from undeveloped reversed-phase thin layer chromatography plates using a
Neil A Devenport1, James C Reynolds, Daniel J Weston
1Centre for Analytical Science, Department of Chemistry, Loughborough University, Leicestershire, LE11 3TU, UK.
Abstract:
The direct extraction of urinary analytes deposited on reversed-phase thin-layer chromatography (RP-TLC) plates is demonstrated using a solvent gradient extraction procedure without prior chromatographic development. The surface sample probe TLC-MS interface used for the gradient extraction is compared to direct loop injection into the electrospray ion source for biofluid profiling. The gradient elution is shown to enhance ion intensities, as urinary salts are eluted in aqueous formic acid in the early part of the gradient reducing ion suppression. The retention of urinary components on the C18 RP-TLC plate was confirmed by monitoring analyte responses with, and without, an aqueous wash phase prior to the solvent gradient extraction. The use of gradient elution allows fractionation of the complex biological matrix as a result of differential retention of urine components on the undeveloped RP-TLC plate. The direct gradient analysis of TLC plates has also been combined with ion mobility-mass spectrometry to further resolve the complex urinary profile and identify co-eluting compounds.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...