Troubleshooting and Quality Assurance in Hyperpolarized Xenon Magnetic Resonance Imaging: Tools for High-Quality Image Acquisition
Published on: January 5, 2024
Minimum requirement of artificial noise level for using noise-assisted correlation algorithm to suppress artifacts in
1Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan, ROC. tsuiph@mail.cgu.edu.tw
Abstract:
The Nakagami image is a complementary imaging mode for pulse-echo ultrasound B-scan to characterize tissues. White noise in anechoic areas induces artifacts in the Nakagami image. Recently, we proposed a noise-assisted correlation algorithm (NCA) for suppressing the Nakagami artifact. In the NCA, artificial white noise is intentionally added twice to backscattered signals to produce two noisy data, which are used to establish a correlation profile for rejecting noise. This study explored the effects of artificial noise level on the NCA to suppress the artifact of the Nakagami image. Simulations were conducted to produce B-mode images of anechoic regions under signal-to-noise ratios (SNRs) of 20, 10 and 5 dB. Various artificial noise levels ranging from 0.1- to 1-fold of the intrinsic noise amplitude were used in the NCA for constructing the Nakagami images. Phantom experiments were conducted to validate the performance of using the optimal artificial noise level suggested by the simulation results to suppress the Nakagami artifacts by the NCA. The simulation results indicated that the artifacts of the Nakagami image in the anechoic regions can be gradually suppressed by increasing the artificial noise level used in the NCA to improve the image contrast-to-noise ratio (CNR). The CNR of the Nakagami image reached 20 dB when the artificial noise level was 0.7-fold of the intrinsic noise amplitude. This criterion was demonstrated by the phantom results to provide the NCA with an excellent ability to obtain artifact-free Nakagami images.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
07:47Use of Sacrificial Nanoparticles to Remove the Effects of Shot-noise in Contact Holes Fabricated by E-beam Lithography
Published on: February 12, 2017
Related Concept Videos
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and hence a...
Upsampling