Related Experiment Video
Updated: May 21, 2026

An Educational Video Demonstration of How to Prone a Critically Ill Intubated Patient
Published on: November 30, 2022
[Decubitus prone position in patient with extracorporeal CO2 removal device Novalung(®)]
M J Frade Mera1, L Vergara Díez, N Fernández Gaute
1Servicio de Medicina Intensiva, Polivalente del Hospital Universitario 12 de Octubre, Madrid, España. mariajesusfrade@yahoo.es
Objective:
To describe the course of a patient with the extracorporeal CO2 removal device and discover the effect of Novalung on ventilation, considering the patient's prone position and its influence on the device's blood flow. To develop a protocol of managing and specific care of a patient with Novalung.
Material And Methods:
A case report of a patient with Novalung in a tertiary hospital ICU unit is reported. Parameters considered are hemodynamic, respiratory, pharmacological, analytical, neuromonitoring, managing of the Novalung and length of decubitus prone cycles. Anova Test, Student's T test, Wilcoxon-Mann Whitney and Spearman correlation. Significance p <0.05.
Results:
A 46-year old women with nosocomial pneumonia and acute respiratory failure with indication of Novalung to decrease hypercapnia and optimize ventilatory management of refractory hypoxemia. ICU Stay 26 days, MBP 82 ± 9 mmHg, HR 110 ± 6l pm during the admission, monitoring PICCO 5 days CI 3.2 ± 0.8 l/min/m2, ELWI 33 ± 4 ml, continuous hemofiltration 13.2 days with a median removal 50 cc/h. Norepinephrine dose 0.68 ± 0.79 μ/kg/min for 15 days. Respiratory parameters during the admission: PO2 59 ± 13 mmHg, PCO2 68 ± 35 mmHg, SatO2 85 ± 12%, PO2/FIO2 69 ± 35, tidal volume 389 ± 141 cc. Novalung® 13 days, heparin dose 181.42 ± 145 mIU/Kg/min, Cephalin time 57.56 ± 16.41 sec, O2 flow 7 ± 3 l/min, median blood flow 1030 cc/h, interquartile range 1447-612 cc/h. Prone cycles 4, duration 53 ± 27 hours. With Novalung® PCO2 decreased regardless of position 66 ± 21:56 ± 9, p=0.005. Tidal volume 512 ± 67:267 ± 72, p=0.0001. Blood flow on supine-prone position 1053 ± 82:113 ± 112, p=0.001. There was no link between blood flow and PCO2 (p=0.2) and between O2 and PO2 flow (p=0.05). Specific care: pedal and tibial pulse monitoring, keep circuit safe to prevent and detect signs of bleeding, femoral arterial and venous catheter care, coagulation monitoring.
Comments:
During the use of Novalung protective, ventilation, low tidal volumes, decreased pressure plateau, PEEP and hypercapnia were achieved. Blood flow decreased in prone position, but the PCO2 did not increase. The device did not coagulate.
Related Concept Videos
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis