Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
Is confidence of mammographic assessment a good predictor of accuracy?
Berta M Geller1, Andy Bogart, Patricia A Carney
1Department of Family Medicine, University of Vermont, 1 S Prospect St, Burlington, VT 05401-3444, USA. berta.geller@uvm.edu
Objective:
Interpretive accuracy varies among radiologists, especially in mammography. This study examines the relationship between radiologists' confidence in their assessments and their accuracy in interpreting mammograms.
Materials And Methods:
In this study, 119 community radiologists interpreted 109 expert-defined screening mammography examinations in test sets and rated their confidence in their assessment for each case. They also provided a global assessment of their ability to interpret mammograms. Positive predictive value (PPV) and negative predictive value (NPV) were modeled as functions of self-rated confidence on each examination using log-linear regression estimated with generalized estimating equations. Reference measures were cancer status and expert-defined need for recall. Effect modification by weekly mammography volume was examined.
Results:
Radiologists who self-reported higher global interpretive ability tended to interpret more mammograms per week (p = 0.08), were more likely to specialize (p = 0.02) and to have completed a fellowship in breast or women's imaging (p = 0.05), and had a higher PPV for cancer detection (p = 0.01). Examinations for which low-volume radiologists were "very confident" had a PPV of 2.93 times (95% CI, 2.01-4.27) higher than examinations they rated with neutral confidence. Trends of increasing NPVs with increasing confidence were significant for low-volume radiologists relative to noncancers (p = 0.01) and expert nonrecalls (p < 0.001). A trend of significantly increasing NPVs existed for high-volume radiologists relative to expert nonrecall (p = 0.02) but not relative to noncancer status (p = 0.32).
Conclusion:
Confidence in mammography assessments was associated with better accuracy, especially for low-volume readers. Asking for a second opinion when confidence in an assessment is low may increase accuracy.
More Related Videos
Related Concept Videos
Interpretation of Confidence Intervals
Confidence intervals have confidence coefficients that are crucial for their interpretation. The most common confidence coefficients are 0.90, 0.95, and 0.99, which can be written as percentages–90%, 95%, and 99%, respectively.
Suppose a person calculates a confidence interval with a confidence coefficient of 0.95. In that case, they can...
Receiver Operating Characteristic Plot
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Confidence Coefficient
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT