Related Experiment Video
Updated: May 21, 2026

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Repair of prosthetic mitral valve paravalvular leak using an off-pump transapical approach
Vinod H Thourani1, Colleen M Smith, Robert A Guyton
1Division of Cardiothoracic Surgery, Joseph B. Whitehead Department of Surgery, Emory University School of Medicine, Atlanta, Georgia 30308, USA. vthoura@emory.edu
Abstract:
Patients who present with significant paravalvular regurgitation after mitral valve replacement remain a difficult patient population and high-risk surgical candidates. We present 3 cases of transapical closure of mitral valve paravalvular leak (PVL) after mitral valve replacement using Amplatzer closure devices (AGA Medical Corp, Plymouth, MN). All 3 patients experienced decreased regurgitation at the site of the closure as well as symptomatic improvement in their heart failure.
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Regurgitation III: Medical Management
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Regurgitation I: Introduction