A novel control strategy to improve the performances of heated wire humidifiers in artificial neonatal ventilation
E Schena1, P Saccomandi, C Ramandi
1Center for Integrated Research, Unit of Measurements and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, via Alvaro del Portillo 21, 00128, Rome, Italy.
Abstract:
Controlling thermo-hygrometric conditions of gas delivered in neonatal mechanical ventilation shows some unresolved issues due to the design and control strategies implemented in heated wire humidifiers. We perform an in vitro evaluation of humidifier performances, which use a control strategy based on a single-point temperature as feedback, and propose a novel design of the control which consists in pre-warming the gas upwards in the humidification chamber. The ad hoc developed control approach based on a theoretical model is implemented in vitro with and without pre-warming for comparative purposes. Without pre-warming, gas at the chamber outlet needs further post-warming and, depending on the flow rate, the vapour content condensates along the breathing circuit. Whereas, with pre-warming, the proposed control strategy allows us to considerably improve steady-state thermo-hygrometric conditions (T = 37 ± 1 °C, RH = 96% ± 4%) of gas, reaching the Y-piece near to ideal ones in the whole flow rate range, even though a high inlet chamber temperature is required at low flow rate values. The proposed solution, as theoretically predicted, also allows us to limit the vapour condensation along the circuit.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Neural Control of Respiration
Respiratory Centers in the Brainstem
Two primary areas comprise the respiratory center: the medullary respiratory center in the medulla oblongata and the pontine respiratory group in the pons. The...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...