Related Experiment Video
Updated: May 21, 2026

Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators
Published on: May 30, 2014
A perceptually relevant channelized joint observer (PCJO) for the detection-localization of parametric signals
Lu Zhang1, Christine Cavaro-Ménard, Patrick Le Callet
1Laboratory Lisa, University of Angers, Angers, France. lu.ge@etud.univ-angers.fr
Abstract:
Many numerical observers have been proposed in the framework of task-based approach for medical image quality assessment. However, the existing numerical observers are still limited in diagnostic tasks: the detection task has been largely studied, while the localization task concerning one signal has been little studied and the localization of multiple signals has not been studied yet. In addition, most existing numerical observers need a priori knowledge about all the parameters of the underdetection signals, while only a few of them need at least two signal parameters. In this paper, we propose a novel numerical observer called the perceptually relevant channelized joint observer (PCJO), which cannot only detect but also localize multiple signals with unknown amplitude, orientation, size and location. We validated the PCJO for predicting human observer task performance by conducting a clinically relevant free-response subjective experiment in which six radiologists (including two experts) had to detect and localize multiple sclerosis (MS) lesions on magnetic resonance (MR) images. By using the jackknife alternative free-response operating characteristic (JAFROC) as the figure of merit (FOM), the detection-localization task performance of the PCJO was evaluated and then compared to that of the radiologists and two other numerical observers--channelized hotelling observer (CHO) and Goossenss CHO for detecting asymmetrical signals with random orientations. Overall, the results show that the PCJO performance was closer to that of the experts than to that of the other radiologists. The JAFROC1 FOMs of the PCJO (around 0.75) are not significantly different from those of the two experts (0.7672 and 0.7110), while the JAFROC1 FOMs of the numerical observers mentioned above (always over 0.84) outperform those of the experts. This indicates that the PCJO is a promising method for predicting radiologists' performance in the joint detection-localization task.
Related Concept Videos
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the system's...
Functional Classification of Joints
The functional classification of joints is determined by the amount of mobility between the adjacent bones. Joints are functionally classified as a synarthrosis or immobile joint, an amphiarthrosis or slightly moveable joint, or as a diarthrosis, a freely moveable joint. Fibrous and cartilaginous joints can be functionally classified as either synarthroses or amphiarthroses, whereas all synovial joints are classified as diarthroses.
Synarthrosis
An immobile...
Structural Classification of Joints
A fibrous joint is where the adjacent bones are united by fibrous connective...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.