Related Experiment Video
Updated: May 21, 2026

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Ultrahigh-sensitivity infrared detection system using an InGaAs p-i-n photodiode with low dielectric polarization
Makoto Akiba1, Yoshikazu Kanai
1National Institute of information and Communications Technology, 4-2-1 Nukui-Kitamachi, Koganei, Tokyo 184-8795, Japan. akiba@nict.go.jp
Abstract:
We developed a highly sensitive infrared photodetection system using an InGaAs p-i-n photodiode. The temperature and data sampling rate dependences of the readout noise were measured to determine the optimum temperature for low-noise detection. The optimum temperature for sampling rates below 100 Hz was 100 K, and the readout noise at 1 Hz was 2.5 e. The readout noise at 1 MHz and 140 K was 49.4 e. The light detection limit of the system was 8.2×10(-19) W at a wavelength of 1.3 μm. The spectral noise densities of a readout circuit were measured in order to determine the origin of noise.
Related Concept Videos
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Gas Chromatography: Types of Detectors-II