Related Experiment Video
Updated: May 20, 2026

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Stress distribution in the peri-implant bone with splinted and non-splinted implants by in vivo loading data-based
Ryuji Shigemitsu1, Toru Ogawa, Tetsuya Matsumoto
1Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai, 980-8575, Japan, shigemitsu@dent.tohoku.ac.jp.
Abstract:
The aim of this study was to evaluate stress distribution in peri-implant bone and to investigate the influence of splinting implants by finite element analysis (FEA) with in vivo loading data. The magnitude and direction of the force exerted on implants during maximal voluntary clenching of a subject were recorded with 3-D piezoelectric force transducers. FEA using in vivo loading data was conducted on splinted and non-splinted models with two implants. Overall, the splinted model reduced stress in peri-implant bone in comparison with the non-splinted model.