Related Experiment Video
Updated: May 20, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Evaluation of compound-independent calibration using gas chromatography with atomic emission detection
1Department of Chemistry, Fudan University, 200433 Shanghai, PR China.
Abstract:
The evaluation of compound-independent calibration (CIC) using gas chromatography (GC) with atomic emission detection (AED) is demonstrated by the identification of several sulfur or nitrogen compounds. Among other GC detectors, the advantage of using the AED is the selectivity of detection. Because contradictory results have been reported for the determination of numeric atomic ratios of elements, we set up a study with the objectives not only of applying these techniques but of determining under which conditions they will yield satisfactory results. The column pressure dependence of AED response is demonstrated through studies performed with constant pressure of 20, 30, and 40 psi. Moreover, the data collected in this study are evidence that inter-elements response factor ratios, particularly for the C/S, is very dependent on the molecular mass and concentration of the chemicals analysed whereas molecular structure seems to have less effect on the AED signal. We therefore suggest the use of a reference set of compounds covering a large chromatographic window, which enables the selection, within this set, of the most appropriate reference compound for calibration and for determination of the raw formula of an unknown analyte.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...

