Related Experiment Video
Updated: May 20, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Multi-component trace analysis of organic xenobiotics in surface water containing suspended particular matter by
Christine Erger1, Peter Balsaa, Friedrich Werres
1IWW Water Centre, Moritzstrasse 26, 45476 Mülheim an der Ruhr, Germany. christine.erger@uni-due.de
Abstract:
Suspended particulate matter (SPM) often disturbs the analysis of surface water by conventional methods, such as liquid-liquid extraction (LLE) or solid phase extraction (SPE), caused by insufficient extraction or by plugging. Water and SPM are therefore often separately analysed, which is associated with high expenditure of time, work and costs. Hence, SPM is partly ignored, if the fraction of sorptively bound analytes is small compared to the total analyte concentration. However, the European Water Framework Directive (WFD, Directive 2000/60/EC) requires explicitly an investigation of the whole water sample including SPM, because many priority and priority hazardous substances can sorb substantially to SPM. Therefore, an SPE disk based method was developed for the determination of 54 priority and priority hazardous pollutants including polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), polybrominated diphenyl ethers (PBDE), organic chlorinated pesticides (OCP) and other pesticides in surface water containing SPM. The developed SPE disk method allows analysis of 1L surface water containing up to 1000 mg SPM without prior separation of SPM in about 2h including gas chromatography-mass (GC-MS) spectrometry analysis. The limits of quantification vary in a range of 0.8 to 38 ng/L.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
High-Performance Liquid Chromatography: Types of Detectors