Doppler Ultrasound-Based Leg Blood Flow Assessment During Single-Leg Knee-Extensor Exercise in an Uncontrolled Setting
Published on: December 15, 2023
[Ankle brachial pressure index (ABPI): color-Doppler versus ultrasound Doppler correlation study in 98 patients after
S Gestin1, A Delluc, A H Saliou
1Unité d'écho-Doppler et de médecine vasculaire, CHU La Cavale-Blanche, boulevard Tanguy-Prigent, 29609 Brest cedex, France.
Objective:
Ankle Brachial Pressure Index (ABPI) by Doppler ultrasound is the gold standard non invasive method for screening of peripheral arterial disease (PAD). This reference method is little used in routine practice, particularly by vascular disease specialists since the most recent ultrasound devices no longer have continuous wave probes. The purpose of our survey was to assess interobserver reproducibility of color-Doppler measurements made in a first population, then second, to assess the correlation between ABPI measurements made with color-Doppler and with ultrasound Doppler in a second population.
Methods:
One hundred twenty patients meeting screening criteria for AOMI defined by the French Health Authorities (HAS, 2006) participated in the study between October 2010 and April 2011 in the Echo Doppler and Vascular Medicine unit of the Brest University teaching hospital: 22 patients for interobserver reproducibility and 98 for color-Doppler - continuous Doppler correlation study. Two independent operators measured the ABPI index in each of the 98 patients using color-Doppler and continuous Doppler in random order, producing 353 measurements. Reliability and reproducibility were assessed using the intraclass correlation coefficient of correlation (ICC) determined with Spearman and the Bland-Altman methods.
Results:
The ABPI was less than 0.90 in 62% of patients. The color-Doppler reproducibility study showed a mean difference of 0.02 [95% CI: -0.02 to 0.17] using the Bland Altman method with ICC equal to 0.89 (P<0.001). For the intermethod correlation study, the mean difference was 0.03 [95% CI: -0.17 to 0.23], with ICC equal to 0.84 (P<0.001).
Conclusion:
Color-Doppler could be an alternative to Doppler ultrasound for PAD screening or follow-up, depending on the results of further evaluations in larger populations.
More Related Videos
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.