Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Two-dimensional gas chromatography with heart-cutting for isotope ratio mass spectrometry analysis of steroids in
A D Brailsford1, I Gavrilović, R J Ansell
1King's College London, UK. alan.brailsford@kcl.ac.uk
Abstract:
The accuracy and precision of gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) measurements are highly dependent on analyte purity. Reliable analysis of urinary steroids for doping control therefore requires extensive and time-consuming sample preparation (i.e. liquid chromatography fraction collection) prior to GC-C-IRMS analysis. The use of two-dimensional GC (GC-GC) with heart-cutting (Deans Switch) as a possible approach to reduce the sample purification required for IRMS analysis is described herein. The system uses a low thermal mass oven (LTM) incorporated into an existing GC-C-IRMS system. GC-GC allowed the use of a cyanopropyl/phenyl column in the first dimension to optimize the separation of underivatized steroids, while a phenyl-methylpolysiloxane column in the second dimension focuses the selectively cut analytes into narrower peaks for more sensitive and reliable MS analysis. In addition, to confirm analyte identity, eluent from the second GC was split, with 20 % entering a scanning MS, and 80 % flowing to the IRMS. As a proof concept, the developed method was then used to analyze a single spot urine (5 ml) from an individual receiving T therapy (2 × 50 mg sachets of Testogel(®)). The T delta value (-27.8 ‰, [T] = 38 ng/ml) was clearly distinct from 11-ketoetiocholanolone (-22.5 ‰) (used as an endogenous reference compound (ERC)), indicating T as being of exogenous origin. The simultaneous analysis by the scanning MS yielded a full scan mass spectrum of the same chromatographic peak, thus confirming the peak to be T.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...