Improved separation of complex polycyclic aromatic hydrocarbon mixtures using novel column combinations in GC ×
Carlos Manzano1, Eunha Hoh, Staci L Massey Simonich
1Department of Chemistry, Oregon State University, Corvallis, Oregon, USA.
Abstract:
Complex mixtures of polycyclic aromatic hydrocarbons (PAHs) are difficult to resolve because of the high degree of overlap in compound vapor pressures, boiling points, and mass spectral fragmentation patterns. The objective of this research was to improve the separation of complex PAH mixtures (including 97 different parent, alkyl-, nitro-, oxy-, thio-, chloro-, bromo-, and high molecular weight PAHs) using GC × GC/ToF-MS by maximizing the orthogonality of different GC column combinations and improving the separation of PAHs from the sample matrix interferences, including unresolved complex mixtures (UCM). Four different combinations of nonpolar, polar, liquid crystal, and nanostationary phase columns were tested. Each column combination was optimized and evaluated for orthogonality using a method based on conditional entropy that considers the quantitative peak distribution in the entire 2D space. Finally, an atmospheric particulate matter with diameter <2.5 μm (PM(2.5)) sample from Beijing, China, a soil sample from St. Maries Creosote Superfund Site, and a sediment sample from the Portland Harbor Superfund Site were analyzed for complex mixtures of PAHs. The highest chromatographic resolution, lowest synentropy, highest orthogonality, and lowest interference from UCM were achieved using a 10 m × 0.15 mm × 0.10 μm LC-50 liquid crystal column in the first dimension and a 1.2 m × 0.10 mm × 0.10 μm NSP-35 nanostationary phase column in the second dimension. In addition, the use of this column combination in GC × GC/ToF-MS resulted in significantly shorter analysis times (176 min) for complex PAH mixtures compared to 1D GC/MS (257 min), as well as potentially reduced sample preparation time.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: