Related Experiment Video
Updated: May 20, 2026

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Comparing the diagnostic yields of technologists and radiologists in an invitational colorectal cancer screening
Margriet C de Haan1, C Yung Nio, Maarten Thomeer
1Department of Radiology, Academic Medical Center, University of Amsterdam, PO Box 22700, 1100 DE Amsterdam, the Netherlands. margrietcdehaan@gmail.com
Purpose:
To compare the diagnostic yields of a radiologist and trained technologists in the detection of advanced neoplasia within a population-based computed tomographic (CT) colonography screening program.
Materials And Methods:
Ethical approval was obtained from the Dutch Health Council, and written informed consent was obtained from all participants. Nine hundred eighty-two participants (507 men, 475 women) underwent low-dose CT colonography after noncathartic bowel preparation (iodine tagging) between July 13, 2009, and January 21, 2011. Each scan was evaluated by one of three experienced radiologists (≥800 examinations) by using primary two-dimensional (2D) reading followed by secondary computer-aided detection (CAD) and by two of four trained technologists (≥200 examinations, with colonoscopic verification) by using primary 2D reading followed by three-dimensional analysis and CAD. Immediate colonoscopy was recommended for participants with lesions measuring at least 10 mm, and surveillance was recommended for participants with lesions measuring 6-9 mm. Consensus between technologists was achieved in case of discordant recommendations. Detection of advanced neoplasia (classified by a pathologist) was defined as a true-positive (TP) finding. Relative TP and false-positive (FP) fractions were calculated along with 95% confidence intervals (CIs).
Results:
Overall, 96 of the 982 participants were referred for colonoscopy and 104 were scheduled for surveillance. Sixty of 84 participants (71%) referred for colonoscopy by the radiologist had advanced neoplasia, compared with 55 of 64 participants (86%) referred by two technologists. Both the radiologist and technologists detected all colorectal cancers (n = 5). The relative TP fraction (for technologists vs radiologist) for advanced neoplasia was 0.92 (95% CI: 0.78, 1.07), and the relative FP fraction was 0.38 (95% CI: 0.21, 0.67).
Conclusion:
Two technologists serving as a primary reader of CT colonographic images can achieve a comparable sensitivity to that of a radiologist for the detection of advanced neoplasia, with far fewer FP referrals for colonoscopy.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
