Related Experiment Video
Updated: May 20, 2026

Spinal Sonography for Ultrasound-Guided Lumbar Neuraxial Anesthesia
Published on: January 31, 2025
Comparison of Spinal Block Levels between Laboring and Nonlaboring Parturients Using Combined Spinal Epidural
Yu-Ying Tang1, Jie Zhou, Xiao-Hui Ren
1Department of Anesthesiology, West China Second Hospital, Sichuan University, Sichuan, Chengdu 610041, China.
Background. It was suggested that labor may influence the spread of intrathecal bupivacaine using combined spinal epidural (CSE) technique. However, no previous studies investigated this proposition. We designed this study to investigate the spinal block characteristics of plain bupivacaine between nonlaboring and laboring parturients using CSE technique. Methods. Twenty-five nonlaboring (Group NL) and twenty-five laboring parturients (Group L) undergoing cesarean delivery were enrolled. Following identification of the epidural space at the L3-4 interspace, plain bupivacaine 10 mg was administered intrathecally using CSE technique. The level of sensory block, degree of motor block, and hemodynamic changes were assessed. Results. The baseline systolic blood pressure (SBP) and the maximal decrease of SBP in Group L were significantly higher than those in Group NL (P = 0.002 and P = 0.03, resp.). The median sensory level tested by cold stimulation was T6 for Group NL and T5 for Group L (P = 0.46). The median sensory level tested by pinprick was T7 for both groups (P = 0.35). The degree of motor block was comparable between the two groups (P = 0.85). Conclusion. We did not detect significant differences in the sensory block levels between laboring and nonlaboring parturients using CSE technique with intrathecal plain bupivacaine.
Background. It was suggested that labor may influence the spread of intrathecal bupivacaine using combined spinal epidural (CSE) technique. However, no previous studies investigated this proposition. We designed this study to investigate the spinal block characteristics of plain bupivacaine between nonlaboring and laboring parturients using CSE technique. Methods. Twenty-five nonlaboring (Group NL) and twenty-five laboring parturients (Group L) undergoing cesarean delivery were enrolled. Following identification of the epidural space at the L3-4 interspace, plain bupivacaine 10 mg was administered intrathecally using CSE technique. The level of sensory block, degree of motor block, and hemodynamic changes were assessed. Results. The baseline systolic blood pressure (SBP) and the maximal decrease of SBP in Group L were significantly higher than those in Group NL (P = 0.002 and P = 0.03, resp.). The median sensory level tested by cold stimulation was T6 for Group NL and T5 for Group L (P = 0.46). The median sensory level tested by pinprick was T7 for both groups (P = 0.35). The degree of motor block was comparable between the two groups (P = 0.85). Conclusion. We did not detect significant differences in the sensory block levels between laboring and nonlaboring parturients using CSE technique with intrathecal plain bupivacaine.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Local Anesthetics: Differential Sensitivity of Nerve Fibers
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia
Depolarizing Blockers: Pharmocokinetics