Effect of thermal desorption kinetics on vapor injection peak irregularities by a microscale gas chromatography
Jung Hwan Seo1, Jing Liu, Xudong Fan
1Engineering Research Center for Wireless Integrated Microsensing and Systems, University of Michigan, Ann Arbor, Michigan 48109, USA.
Abstract:
Microscale gas chromatography (μGC) is an emerging analytical technique for in situ analysis and on-site monitoring of volatile organic compounds (VOCs) in moderately complex mixtures. One of the critical subcomponents in a μGC system is a microfabricated preconcentrator (μ-preconcentrator), which enables detection of compounds existing in indoor/ambient air at low (~sub ppb) concentrations by enhancing their signals. The prevailing notion is that elution peak broadening and tailing phenomena resulting from undesirable conditions of a microfabricated separation column (μ-column) are the primary sources of poor chromatographic resolution. However, previous experimental results indicate that the resolution degradation still remains observed for a μ-column integrated with other μGC subcomponents even after setting optimal separation conditions. In this work, we obtain the evidence that the unoptimized μ-preconcentrator vapor release/injection performance significantly contributes to decrease the fidelity of μGC analysis using our state-of-the-art passive preconcentrator microdevice. The vapor release/injection performance is highly affected by the kinetics of the thermal desorption of compounds trapped in the microdevice. Decreasing the heating rate by 20% from the optimal rate of 90 °Cs(-1) causes a 340% increase in peak tailing as well as 70% peak broadening (30% peak height reduction) to the microscale vapor injection process.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II