Influence of thickness error on the operation of adjustable magneto-optical isolators

Mahmoodreza Sharifian1, Hassan Ghadiri, Mehdi Zamani

  • 1Faculty of Science, Islamic Azad University, North Tehran Branch, Tehran, Iran.

Applied Optics
|July 12, 2012
PubMed

Related Concept Videos

Biasing of Metal-Semiconductor Junctions01:27

Biasing of Metal-Semiconductor Junctions

Biasing metal-semiconductor junctions involves applying a voltage across the junction. Specifically, the metal is connected to a voltage source, while the semiconductor is grounded. This technique is essential for controlling the direction and magnitude of current flow in electronic devices, including diodes, transistors, and photovoltaic cells.
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft01:23

Design Example: Deciding Thickness of Lubricating Fluid in a Shaft

Effective lubrication between a rotating shaft and its bearing housing is essential in rotating machinery to minimize friction, wear, and energy loss. With carefully controlled thickness and viscosity, the lubricant layer prevents metal-to-metal contact, ensuring smooth operation.
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
Uncertainty in Measurement: Reading Instruments02:46

Uncertainty in Measurement: Reading Instruments

Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...