Related Experiment Video
Updated: May 20, 2026

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Optic nerve head circulation determined by pulse wave analysis is significantly correlated with cardio ankle vascular
Tomoaki Shiba1, Mao Takahashi, Yuichi Hori
1Department of Ophthalmology, Toho University Sakura Medical Center Chiba, Japan. tomoaki-s@sakura.med.toho-u.ac.jp
Aim:
To determine whether there is a significant correlation between optic nerve head circulation determined by pulse wave analysis of laser speckle flowgraphy (LSFG), and the cardio-ankle vascular index (CAVI), left ventricular (LV) function, and age.
Methods:
Forty-nine men who visited the Vascular Function Section of Toho University Sakura Medical Center, Chiba, Japan were studied. The mean age of the subjects was 60.7±10.6 years (range 29 to 80 years). The CAVI, left ventricular ejection fraction (LVEF) as a function of the systolic LV function, early diastolic mitral annulus velocity (e'), and the ratio of transmitral early peak velocity (E) to e' (E/e' ratio) as the diastolic LV function, and the optic nerve head circulation determined by pulse wave analysis of the LSFG. This parameter was named the blowout time (BOT).
Results:
The BOT was significantly correlated with age, heart rate, body mass index (BMI), triglyceride, LVEF, e' velocity, E/e' ratio, and CAVI. The results of multiple regression analysis showed that age was significantly associated with CAVI (r= 0.36, p=0.002), BOT (r=-0.30, p=0.01) and e' velocity (r=-0.21, p=0.04).
Conclusions:
The BOT of the optic nerve head circulation determined by LSFG was significantly correlated with age but was independent of cardiac diastolic function and arterial stiffness. This suggests that the damage to different organs increases with age. Our results confirmed that BOT can be helpful in evaluating physiological aging of the microcirculation.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Pulse Assessment Sites
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...