Related Experiment Video
Updated: May 20, 2026

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Real-time three-dimensional transesophageal echocardiography: improvements in intraoperative mitral valve imaging
Maximilian Dominik Hien1, Helmut Rauch, Artur Lichtenberg
1Department of Pediatrics, Research Training Group 1126, Heidelberg University, Neckarstaden 18, 69117 Heidelberg, Germany. maximilian.hien@med.uni-heidelberg.de
Background:
Successful surgical repair of a regurgitant mitral valve (MV) is dependent on a comprehensive assessment of its complex anatomy. Although there is limited evidence of the feasibility and accuracy of intraoperative real-time 3-dimensional transesophageal echocardiography (RT3DTEE) in MV surgery, its use is increasing worldwide. We designed this prospective observational study of patients with mitral regurgitation to test initial findings on the accuracy of RT3DTEE images in the diagnosis of MV prolapse and chordal rupture relative to 2D imaging and to assess the potential of RT3DTEE for visualizing leaflet clefts.
Methods:
TEE-certified anesthesiologists examined 62 consecutive patients undergoing MV surgery by acquiring a full standard set of 2D TEE sections and 3D zoom recordings. Offline, 2D and 3D images were presented independently and in randomized order to 2 expert interpreters. Accuracy was determined using the surgical findings as the "gold standard."
Results:
Surgical inspection identified 52 cases of MV prolapse (MVP). RT3DTEE correlated stronger with the surgical findings than 2D TEE for detection and localization of MVP (difference in proportions=33.9%, P<0.001) and chordal rupture (difference in proportions=25.8%, P<0.001). The superiority of RT3DTEE was significant for scallops A2, P1, P2 in MVP and A2, P2 in chordal rupture (all P<0.05). In 22 patients, leaflet clefts were also surgically repaired, and RT3DTEE was feasible in accessing them (κ=0.65, confidence interval [0.44, 0.81]).
Conclusion:
Although 2D TEE is currently the standard tool for intraoperative imaging in MV surgery, RT3DTEE improves the visualization of MV pathology and increases the accuracy of interpretation by facilitating spatial orientation. Further investigations, particularly those aimed at establishing its cost effectiveness, are indicated.
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Mitral Stenosis III: Medical Management
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...