Related Experiment Videos
Evaluation of a novel solid-phase immunoassay, Clearview Chlamydia, for the rapid detection of Chlamydia trachomatis
J T Arumainayagam1, R S Matthews, S Uthayakumar
1Department of Genitourinary Medicine, General Hospital, Birmingham, United Kingdom.
Journal of Clinical Microbiology
|December 1, 1990
Abstract:
Clearview Chlamydia (Unipath Limited, Bedford, United Kingdom) is a rapid immunoassay for the direct detection of Chlamydia trachomatis antigen. This assay was evaluated against the tissue culture method by using 376 paired endocervical specimens. The Clearview assay had a sensitivity of 93.5% and a specificity of 99% when it was compared with the tissue culture method. This assay does not require specialized equipment or trained personnel and yields results within 30 min from the time that a specimen is collected.