Abstract:
Protein recovery from gel electrophoresis plays an important role in functional genomics and proteomics but faces a series of issues (e.g., complex procedure, low recovery, long experimental time). In this study, a monolithic column electroelution (MCE) was developed for protein recovery from gel electrophoresis. With the model proteins of bovine serum albumin (BSA), hemoglobin (Hb), and myoglobin (Mb), the developed device and method were compared with common electroelution procedures in agarose gel electrophoresis (AGE). The comparative experiments revealed that (i) the protein recovery achieved with the developed device was greater than 83%, much higher than the 41% to 50% achieved with the common devices; (ii) the running time to obtain 70% recovery was approximately 15 min, evidently shorter than the 240 min with the common devices; and (iii) the device and procedure were simple and less time-consuming as compared with those of the common devices. It was observed that the serum protein bands cut from polyacrylamide gel electrophoresis could be transferred into solution in 15 to 30 min with 82% yield. The device, along with its relevant procedure, has potential use in protein extraction and proteomics as well as in DNA studies.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Principles Of Column Chromatography
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...