Related Experiment Video
Updated: May 20, 2026

Testing Acetylcholine Followed by Adenosine for Invasive Diagnosis of Coronary Vasomotor Disorders
Published on: February 3, 2021
Estimation of coronary artery stenosis by low-dose adenosine stress real-time myocardial contrast echocardiography: a
Xiao Zhou1, Guang Zhi, Yong Xu
1Echo Lab, Department of Cardiovascular Disease, Chinese People's Liberation Army General Hospital, Beijing 100853, China.
Background:
Coronary microcirculation reserve is an important field in the research of coronary artery disease, but it is difficult to identify clinically. Currently it is widely accepted that myocardial contrast echocardiography (MCE) is a safe, inexpensive method and has comparatively high image resolution. The present study used quantitative low-dose adenosine stress real-time (RT)-MCE to estimate myocardial perfusion and the coronary stenosis.
Methods:
Forty-nine left ventricular (LV) segments from 14 unselected patients were divided into three groups according to the coronary angiography or CT angiography results: group 1 (n = 20, 41%) without significant stenosis (< 70%), group 2 (n = 12, 24%) with successful percutaneous coronary intervention (PCI), and group 3 (n = 17, 35%) with significant stenosis (> 70%). RT-MCE was performed in these patients with low-dose adenosine stress and continuous infusion of Sonovue. The replenishing curves were drawn according to the contrast density measured at the end-diastolic frame of every cardiac circle by ACQ software.
Results:
Forty-nine LV segments with satisfactory image quality were picked for quantitative contrast echo analysis. The replenishing curves were analyzed at baseline and after stress. Perfusion of group 3 did not decrease significantly at baseline, and showed no improvement during adenosine stress and was significantly different from groups 1 and 2 (P < 0.05). The A·β and β increased more significantly in group 1 than in groups 2 and 3 (P < 0.05). In a receiver operating characteristic (ROC) curve analysis, A·β under adenosine stress < 1.74 dB/s had a sensitivity and specificity of 71% for diagnosis of coronary artery stenosis, reduced adenosine-induced rise (percentage of A·β < 81%) had a sensitivity and specificity of 83% and 79% for the diagnosis of low-reserve, and β < 54% had a sensitivity of 86% and specificity of 79%.
Conclusions:
Rest perfusion of severely stenosed arteries may be normal, but adenosine stress can detect the impaired perfusion reserve. Low-dose adenosine stress RT-MCE provides good accuracy for the evaluation of coronary perfusion reserve and hence coronary stenosis.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
