Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
The clinical validity of the spontaneous retinal venous pulsation
Sui Hsien Wong1, Richard Patrick White
1Department of Neurology, The Walton Center NHS Foundation Trust, Liverpool, United Kingdom. suiwong@doctors.org.uk
Background:
The validity of the clinical dictum "the presence of spontaneous retinal venous pulsation (SVP) excludes raised intracranial pressure" has not been previously tested. We set out to determine the specificity and positive predictive value (PPV) of the presence of SVP to indicate normal intracranial pressure (ICP) in a routine clinical setting.
Methods:
We prospectively recruited patients undergoing lumbar puncture (LP), and 2 clinicians were blinded to the indications for LP and cerebrospinal fluid opening pressure (OP). Interobserver reliability was assessed.
Results:
There were 106 patients in our cohort with a median age of 44 years (range, 18-79 years) and median body mass index of 27.5 kg/m (range, 18-48 kg/m). SVP was present in 94 of 106 patients (88.7%). Thirteen of 106 (12.3%) patients had high OP (≥30 cmH2O), and SVP was present in 11 of 13 patients (86%) with high OP. The sensitivity (95% confidence interval) of the presence of SVP to exclude raised ICP was 0.89 (0.88-0.92), specificity of 0.15 (0.05-0.37), PPV of 0.88 (0.87-0.9), and negative predictive value of 0.17 (0.05-0.4). Interobserver agreement was moderate for SVP (kappa = 0.42).
Conclusions:
Although the sensitivity and PPV of the presence of SVP to exclude raised ICP is high, it is not absolute. SVP can be seen in some patients with high ICP. Relying on the presence of SVP to exclude raised ICP may give a false sense of reassurance.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Pulse
The pulse serves as a clinical indicator...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Measurement of Blood Pressure
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...