Related Experiment Video
Updated: May 20, 2026

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Effective radiation dose reduction in computed tomography-guided spinal injections: a prospective, comparative study
Juraj Artner1, Friederike Lattig, Heiko Reichel
1Department of Orthopaedic Surgery, University of Um, RKU, Germany.
Radiation exposure during CT-guided spinal injections can be significantly reduced. A new low-dose protocol achieved an 85% average dose reduction for lumbar epidural and periradicular injections without compromising safety or precision.
Area of Science:
- Radiology
- Medical Imaging
- Interventional Procedures
Background:
- Computed tomography (CT)-guided spinal interventions offer high precision and patient comfort.
- Radiation exposure remains a significant concern, potentially limiting the use of CT-guided procedures.
Purpose of the Study:
- To investigate technical methods for reducing radiation dose in CT-guided lumbar epidural and periradicular injections.
- To evaluate the feasibility of a low-dose protocol for these procedures.
Main Methods:
- A low-dose protocol was developed, involving reduced tube current/energy for topograms and intervention modes, and narrowed scan areas.
- Fifty-three CT-guided lumbar spinal injections were performed using the low-dose protocol.
- Results were compared to 1870 injections performed with a standard dose protocol in 2010.
Main Results:
- An average radiation dose reduction of 85% was achieved with the low-dose protocol.
- The reduction in radiation dose did not negatively impact the safety or precision of the needle placement.
- The protocol was applied to non-obese patients undergoing lumbar epidural and periradicular injections.
Conclusions:
- CT-guided lumbar epidural and periradicular injections can be performed with significantly reduced radiation doses.
- The developed low-dose protocol is effective and safe, addressing concerns about radiation exposure.
- This approach enhances the safety profile of CT-guided spinal interventions.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...