Related Experiment Video
Updated: May 20, 2026

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
A voxel-dose algorithm of heterogeneous activity distribution for Monte-Carlo simulation of radionuclide therapy
Hui Lin1, Jia Jing, Jinfeng Cai
1School of Electronic Science and Application Physics, Hefei University of Technology, Hefei, China. huilin@hfut.edu.cn
Purpose:
The organ or tumor activity is not uniform due to inhomogeneous expression/distributions of receptors/antigens and the nonuniform vascularization of the tumor tissue. However, most patient-specific three-dimensional Monte-Carlo methods for radionuclide dosimetry have dealt with quasi-homogeneous activity distributions. A voxel-by-voxel activity sample algorithm (VM) without artifacts is presented to calculate the dose of the heterogeneous activity distribution for radionuclide dosimetry.
Methods:
The source particle location is sampled according to the activity spatial distribution. The source particle weight is imparted by the relative activity concentration of its origination voxel. This algorithm is applied to calculate the dose volume histogram for multiple independent activity regions with Gauss diffusion activity distributions and then compared with the level partition method (LM). The minimal response and the mean tolerant initial total activity threshold required by tumor control probability and normal tissue complication probability for radioimmunotherapy ((131)I-RIT) also were evaluated by the voxel-by-voxel sample algorithm and the LM. The effective clearance half-time is assumed to be equal to its physical half-life (i.e., 8.02 days for (131)I).
Results:
The result shows that the new algorithm is more consistent with the weighted superposition of the quasi-homogeneous activity distribution than the LM, especially for the multiple independent activity regions composed of different amounts of voxels. The new algorithm effectively avoids the leveling/binning artifacts to the heterogeneous activity distribution. The (131)I-RIT simulation also showed that the minimal response initial total activity threshold of tumors will be much more than the mean tolerant initial total activity threshold of normal organs (e.g., kidney) with the activity heterogeneous grade deteriorating.
Conclusions:
A VM is presented to simulate the dose of the heterogeneous activity distribution for radionuclide dosimetry. The new algorithm effectively avoids the leveling/binning artifacts to the heterogeneous activity distribution.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Radiation: Applications
The average...
Biological Effects of Radiation
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses