Background:
Recommended by current guidelines, red blood cell (RBC) temperature should not exceed 10°C during transport. Since warming is a generically three-dimensional process that is not homogeneous, it is necessary to clarify the term "temperature during warming." The purpose of this study was therefore to investigate laws and relations between surface, mean, and core temperature and the corresponding times when they exceed 10°C during warm-up.
Study Design And Methods:
Time-resolved three-dimensional temperature distributions of 53 resuspended RBC units (mean volume, 253 ± 17 mL) were measured noninvasively by magnetic resonance thermometry. Warm-up temperature maps were visualized and analyzed by dedicated software.
Results:
Mean times when surface, mean, and core temperature exceeded 10°C were 16 ± 4, 24 ± 5, and 36 ± 7 minutes, respectively. Times strongly correlated with each other (r = 0.78-0.95) and their variances mainly depended on RBC storage temperature and RBC pouch width (R(2) = 0.81-0.89). Measured mean temperature time courses were well described by a lumped capacitive model of heat transfer with a sample width-dependent time constant τ(RBC) = 56.3 ± 3.5 minutes (mean R(2) = 0.996).
Conclusion:
Times when RBC surface, mean, and core temperature exceed 10°C can be estimated from each other. Moreover RBC mean temperature can be calculated for arbitrary storage and ambient temperatures. Findings might serve as a helpful tool in RBC temperature monitoring.
Related Concept Videos
Magnetic Resonance Imaging
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...