Low grade squamous intraepithelial lesion, epithelial cell abnormality-adjusted workload, and the ThinPrep imaging
Andrew A Renshaw1, Tarik M Elsheikh
1Department of Pathology, Baptist Hospital of Miami, 8900 N Kendall Dr., Miami, FL 33176, USA. andrewr@baptisthealth.net
The ThinPrep Imaging System (TIS) shows decreased screening sensitivity with higher epithelial cell abnormality (ECA) workloads. Limiting TIS workload to seven ECA-adjusted slides daily optimizes sensitivity for detecting low-grade squamous intraepithelial lesions (LSIL).
Area of Science:
- Cytopathology
- Medical Imaging Technology
- Public Health
Background:
- Previous research indicated a negative correlation between ThinPrep Imaging System (TIS) screening sensitivity and epithelial cell abnormality (ECA) adjusted workload for ASCUS and HSIL detection.
- The relationship between TIS screening sensitivity and ECA-adjusted workload at the LSIL threshold remained less defined.
Purpose of the Study:
- To investigate the correlation between TIS screening sensitivity and ECA-adjusted workload specifically at the threshold for low-grade squamous intraepithelial lesion (LSIL).
- To determine an optimal workload for TIS to achieve maximum screening sensitivity for LSIL detection.
Main Methods:
- Meta-analysis of data from seven published manuscripts containing relevant information on TIS screening.
- Statistical correlation analysis (linear regression) to assess the relationship between changes in TIS sensitivity and ECA-adjusted workload.
- Extrapolation of data to determine workload required for 100% sensitivity at the LSIL threshold.
Main Results:
- A negative correlation was observed between the change in TIS screening sensitivity and ECA-adjusted workload (y = -3.75x + 54, R(2) = 0.104).
- An ECA-adjusted workload of approximately seven slides/day was predicted to achieve 100% sensitivity for LSIL detection.
- This workload is comparable to that achieving 100% sensitivity for ASCUS and slightly higher than for HSIL.
Conclusions:
- The ECA-adjusted workload is a valid metric for assessing TIS workload in LSIL screening.
- Laboratories utilizing TIS should maintain a maximum workload of seven ECA-adjusted slides per day to ensure optimal screening sensitivity.
- Recommended maximum daily actual slides: 700/ECA percentage.