Robotic Cochlear Implantation for Direct Cochlear Access
08:06

Robotic Cochlear Implantation for Direct Cochlear Access

Published on: June 16, 2022

Hearing preservation after cochlear implantation using deeply inserted flex atraumatic electrode arrays.

Sharon Tamir1, Evelyne Ferrary, Stéphanie Borel

  • 1Otolaryngology Department, Beaujon Hospital, APHP, Clichy, France.

Audiology & Neuro-Otology
|July 21, 2012
PubMed
Summary

Cochlear implants with Flex arrays enable deep insertion, preserving residual hearing in adults. While some hearing loss occurred post-surgery, the arrays demonstrated reproducible hearing preservation.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Comparison of Manual Versus Robot-Assisted Piston Prosthesis Placement and Crimping in a 3D-Printed Temporal Bone Model.

Laryngoscope investigative otolaryngology·2026
Same author

State of the art in speech perception assessment.

Journal of communication disorders·2026
Same author

Transitional Life Events in Friedreich Ataxia: Differential Age at Onset Perspectives.

Cerebellum (London, England)·2026
Same author

Cerebellar cognitive-affective syndrome in Friedreich Ataxia.

Journal of neurology·2026
Same author

A Patient-Reported Outcome Measure of Communication Difficulties in Friedreich Ataxia: COMATAX.

Cerebellum (London, England)·2026
Same author

Micro-CT Evaluation of Robot-Assisted Insertion of CI632 Implant in Human Cadaveric Temporal Bones.

The Laryngoscope·2026

Area of Science:

  • Otolaryngology
  • Biomedical Engineering
  • Neuroscience

Background:

  • Cochlear implantation aims to restore hearing in individuals with severe to profound hearing loss.
  • Maintaining residual hearing after cochlear implantation is crucial for auditory rehabilitation outcomes.

Purpose of the Study:

  • To evaluate hearing preservation in adult cochlear implant recipients using Flex arrays.
  • To assess the insertion depth and cochlear coverage achieved with Flex arrays.

Main Methods:

  • Retrospective study of 15 adult patients (19 ears) who received cochlear implants with either Flex EAS® or Flex Soft® arrays.
  • Analysis of array insertion length and estimated cochlear coverage.
  • Comparison of pre- and post-operative pure-tone average (PTA) in the low-frequency range (125-1000 Hz).

More Related Videos

Enhanced Cochlear Coverage and Hearing Preservation in High-Frequency Hearing Loss via Electric Acoustic Stimulation with Longer Electrode
03:49

Enhanced Cochlear Coverage and Hearing Preservation in High-Frequency Hearing Loss via Electric Acoustic Stimulation with Longer Electrode

Published on: October 11, 2024

Related Experiment Videos

Last Updated: May 20, 2026

Robotic Cochlear Implantation for Direct Cochlear Access
08:06

Robotic Cochlear Implantation for Direct Cochlear Access

Published on: June 16, 2022

Enhanced Cochlear Coverage and Hearing Preservation in High-Frequency Hearing Loss via Electric Acoustic Stimulation with Longer Electrode
03:49

Enhanced Cochlear Coverage and Hearing Preservation in High-Frequency Hearing Loss via Electric Acoustic Stimulation with Longer Electrode

Published on: October 11, 2024

Main Results:

  • Mean array insertion length was 25 ± 0.9 mm, with a mean cochlear coverage of 435 ± 14.5°.
  • No significant difference in insertion depth or coverage was observed between Flex EAS® and Flex Soft® arrays.
  • Residual low-frequency hearing was initially preserved but showed a significant deterioration post-surgery (55.1 dB pre-op vs. 81.0 dB post-op, p < 0.01).

Conclusions:

  • Both Flex EAS® and Flex Soft® arrays facilitate deep cochlear insertion.
  • These arrays allow for reproducible hearing preservation, despite a post-operative decline in residual low-frequency hearing.