Experience with titanium devices for rib fixation and coverage of chest wall defects
Andrea Billè1, Lawrence Okiror, Wolfram Karenovics
1Department of Thoracic Surgery, Guy's Hospital, London, UK. andrea_bille@hotmail.it
Objectives:
To describe our experience with two new titanium-based devices for chest wall reconstruction and stabilization.
Methods:
A retrospective analysis of 18 consecutive patients (multiple rib fractures n = 9, iatrogenic rib fracture n = 2, lung herniation n = 2, chest wall tumour n = 5) who underwent surgery for rib fractures or chest wall tumours requiring chest wall resection and reconstruction between October 2010 and March 2012 was conducted. Chest wall defects and rib fractures were fixed with titanium clips and bars or titanium plates and screws through a posterolateral thoracotomy.
Results:
There were 12 males, and the median age was 61 years. There were no postoperative deaths. The only postoperative complication observed was a pleural effusion requiring drainage in one patient who had titanium clips for the fixation of multiple traumatic rib fractures. Median length of stay of the drain and median length of hospital stay were 3 days (range 1-6) and 4 days (range 2-42 days), respectively. The average follow-up period of operatively managed patients was 6 months, (range 2-14 months). Two cases of hardware failure occurred in two patients treated for a lung hernia with large chest wall defects involving the anterior costal margin with either devices.
Conclusions:
Titanium devices (clips and bars; screws and plates) are effective and safe for repair of rib fractures and large chest wall defect reconstruction with minimal complications and good long-term results.
More Related Videos
Related Concept Videos
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
The Thoracic Cage: Ribs
Parts of a Typical Rib
A typical rib has a head, neck, and body. The posterior end of the rib is called the head, followed by a narrow neck. The head articulates primarily with the costal facet...
The Thoracic Cage: Sternum
The sternum is the elongated bony structure on the anterior side of the thoracic cage. It consists of three parts: the manubrium, the body, and the xiphoid process.
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...
Pneumothorax-II
Clinical Manifestations: