Related Experiment Video
Updated: May 20, 2026

Diffuse Reflectance Infrared Spectroscopic Identification of Dispersant/Particle Bonding Mechanisms in Functional Inks
Published on: May 8, 2015
Quantitative determination of prednisone in tablets by infrared attenuated total reflection and Raman spectroscopy
Sylwester Mazurek1, Roman Szostak
1University of Wrocław, Department of Chemistry, Wrocław, Poland.
Abstract:
The quantification of prednisone in tablets was performed using partial least squares (PLS) models based on FTIR-attenuated total reflection (ATR) and FT-Raman spectra. To compare the predictive ability of these models, the relative standard error of prediction (RSEP) values were calculated. In the case of prednisone determination from the FT-Raman data, RSEP values of 3.1 and 3.2% for the calibration and validation data sets were obtained. For FTIR-ATR models, which were constructed using five spectra for each sample, these errors amounted to 2.6 and 2.9%, respectively. Four commercial products containing 1, 5, 10, and 20 mg prednisone/tablet were quantified. Concentrations derived from the elaborated models correlated strongly with the results of reference analyses and with the declared values (in parentheses). The analyses gave recoveries of 100.0-101.6% (100.1-103.0%) and 98.1-103.2% (100.4-102.9%) for FTIR-ATR and FT-Raman data, respectively. A successful quantification of prednisolone in tablets containing 5 mg active ingredient/tablet was also performed using the PLS model, which was based on FTIR-ATR spectra, with a recovery of 99.8 (98.8%). Both reported spectroscopic techniques can be used as fast and convenient alternatives to the standard pharmacopeial methods of prednisone and prednisolone quantification in solid dosage forms. However, in the case of FTIR-ATR spectroscopy, it is necessary to repeat measurements several times to obtain sufficiently low quantification errors.
More Related Videos
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Applications of IR Spectroscopy: Overview
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
IR Spectrometers
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...

