Background:
Perinatal asphyxia leading to hypoxic-ischemic encephalopathy (HIE) is a common problem causing multi organ dysfunction including myocardial involvement which can affect the outcome.
Objective:
To evaluate the myocardial dysfunction in neonates having HIE by electrocardiographic(ECG) and cardiac enzymes (CK Total, CK-MB and Troponin I) and find out the relationship with HIE and outcome.
Design/Methods:
This was a hospital based prospective study. Sixty term neonates who had suffered perinatal asphyxia and developed HIE were enrolled. Myocardial involvement was assessed by clinical, ECG, and CK Total, CK-MB and Troponin I measurements.
Results:
Of 60 cases, 13(21.7%) were in mild, 27(45%) in moderate and 20(33.3%) belonged to severe,HIE. ECG was abnormal in 46 (76.7%); of these 19 (41.3%) had grade I, 13 (28.2%) grades II and III each and 1 (2.1%) with grade IV changes. Serum levels of CK Total, CK- MB and Troponin I were raised in 54 (90%), 52 (86.6%) and 48 (80%) neonates, respectively. ECG changes and enzymatic levels showed increasing abnormalities with severity of HIE, and the differences among different grades were significant (p = 0.002, 0.02, <0.001 and 0.004, respectively). Nineteen (32%) cases died during hospital stay. The non- survivors had high proportion of abnormal ECG (p = 0.024), raised levels of CK-MB (p = 0.018) and Troponin I (p = 0.008) in comparison to survivors.
Conclusions:
Abnormal ECG and cardiac enzymes levels are found in HIE and can lead to poor outcome due to myocardial damage Early detection can help in better management and survival of these neonates.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...