Related Experiment Video
Updated: May 20, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Is single reading with computer-aided detection (CAD) as good as double reading in mammography screening? A
Edward Azavedo1, Sophia Zackrisson, Ingegerd Mejàre
1Department of Diagnostic Radiology, Karolinska Institutet, Stockholm, Sweden.
Background:
In accordance with European guidelines, mammography screening comprises independent readings by two breast radiologists (double reading). CAD (computer-aided detection) has been suggested to complement or replace one of the two readers (single reading + CAD).The aim of this systematic review is to address the following question: Is the reading of mammographic x-ray images by a single breast radiologist together with CAD at least as accurate as double reading?
Methods:
The electronic literature search included the databases Pub Med, EMBASE and The Cochrane Library. Two independent reviewers assessed abstracts and full-text articles.
Results:
1049 abstracts were identified, of which 996 were excluded with reference to inclusion and exclusion criteria; 53 full-text articles were assessed for eligibility. Finally, four articles were included in the qualitative analysis, and one in a GRADE synthesis.
Conclusions:
The scientific evidence is insufficient to determine whether the accuracy of single reading + CAD is at least equivalent to that obtained in standard practice, i.e. double reading where two breast radiologists independently read the mammographic images.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT