Multi-timescale Microscopy Methods for the Characterization of Fluorescently-labeled Microbubbles for Ultrasound-Triggered Drug Release
Published on: June 12, 2021
Insonation frequency selection may assist detection and therapeutic delivery of targeted ultrasound contrast agents
Edward Payne1, Andrew Ooi, Richard Manasseh
1Department of Mechanical Engineering, University of Melbourne, VIC 3010, Australia.
Background:
Ultrasound-targeted drug delivery relies on the unique nature of ultrasound contrast agents--they are microbubbles that respond strongly to ultrasound. Intravenously injected microbubbles are smaller than a blood cell. By increasing the ultrasound power, the bubbles can be ruptured at the targeted endothelial wall, locally releasing any molecules in the bubble shell. Furthermore, ultrasound-activated microbubbles are known to cause sonoporation--the process by which ultrasound drives molecules through cellular membranes. However, techniques are required to selectively detect and rupture only those microbubbles on target walls.
Method:
Experiments are presented on the behaviour of microbubbles on walls. For accuracy, imaging measurements are made on model microbubbles larger than contrast agents. Bubble size was varied and the resonant frequency peak determined.
Results:
Microbubbles on walls have a shifted frequency in good agreement with theory: a 20-25% downshift from the frequency when far from walls. Effects other than the presence of the wall account for less than 5% of the shift.
Discussion:
Theory predicts the frequency downshift should be sustained for actual contrast-agent sized bubbles. The effect of real, compliant cell walls requires investigation. An appropriate downshift in the applied ultrasound frequency could selectively tune gene or drug delivery. To make this feasible, it may be necessary to manufacture monodispersed microbubbles.
More Related Videos
09:05Generation and Quantitative Analysis of Pulsed Low Frequency Ultrasound to Determine the Sonic Sensitivity of Untreated and Treated Neoplastic Cells
Published on: July 22, 2015
14:10Contrast Ultrasound Targeted Treatment of Gliomas in Mice via Drug-Bearing Nanoparticle Delivery and Microvascular Ablation
Published on: December 15, 2010
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...