Increasing the isolated quantities and purities of volatile compounds by using a triple Deans-switch multidimensional
Danilo Sciarrone1, Sebastiano Pantò, Carla Ragonese
1Dipartimento Farmaco-chimico, Facoltà di Farmacia, Università di Messina, viale Annunziata, 98168 Messina, Italy.
Abstract:
A novel preparative-scale triple gas chromatographic system, equipped with three Deans-switch devices, is herein described. The isolation of volatile compounds was achieved by using a lab-made collection system. Considerations are made on the possibility to inject high volumes of neat sample, maintaining, at the same time, high resolution levels. The degree of recovery of a series of compounds, characterized by a differing volatility, is also reported. In this respect, different collection conditions were evaluated, namely, the presence (or not) of packing material as well as CO(2) cooling, in various combinations. Finally, the interconnected features, that is time requirements and the isolation of "acceptable" analyte quantities (e.g., milligram level for NMR characterization), are related to parameters such as analyte concentration, injected volume, collection conditions, and number of GC runs. The results herein reported will demonstrate the need for a high-resolution GC step, prior to analyte collection, in the prep-GC analysis of complex samples.
More Related Videos
11:25Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...