Related Experiment Video
Updated: May 20, 2026

A Retrograde Implantation Approach for Peritoneal Dialysis Catheter Placement in Mice
Published on: July 20, 2022
A combination of biocompatible peritoneal dialysis solutions and residual renal function, peritoneal transport, and
Sing Leung Lui1, Susan Yung, Andrew Yim
1Department of Medicine, Tung Wah Hospital, Hong Kong SAR, People's Republic of China.
Background:
The benefits of biocompatible peritoneal dialysis (PD) fluids, particularly for residual renal function (RRF), are controversial. Moreover, the clinical effects of a PD regimen consisting of different biocompatible PD fluids have not been fully established.
Study Design:
Prospective, randomized, controlled, open-label study.
Setting & Participants:
Patients with end-stage kidney disease newly started on continuous ambulatory PD therapy (N = 150).
Intervention:
A 12-month intervention with 3 biocompatible PD fluids (a neutral-pH, low glucose degradation product, 1.5% glucose solution; a solution with 1.1% amino acid; and a fluid with 7.5% icodextrin) or conventional PD fluid.
Outcomes:
The primary outcome was change in RRF and daily urine volume. Secondary outcomes were peritoneal transport and inflammation markers.
Measurements:
RRF, daily urine volume, serum and dialysate cytokine levels.
Results:
RRF(3.24 ± 1.98 vs 2.88 ± 2.43 mL/min/1.73 m(2); P = 0.9) and rate of decline in RRF (-0.76 ± 1.77 vs -0.91 ± 1.92 mL/min/1.73 m(2) per year; P = 0.6) did not differ between the biocompatible- and conventional-PD-fluid groups. However, patients using the biocompatible PD fluids had better preservation of daily urine volume (959 ± 515 vs 798 ± 615 mL/d in the conventional group, P = 0.02 by comparison of difference in overall change by repeated-measures analysis of variance). Their dialysate-plasma creatinine ratio at 4 hours was higher at 12 months (0.78 ± 0.13 vs 0.68 ± 0.12; P = 0.01 for comparison of the difference in overall change by repeated-measures analysis of variance). They also had significantly higher serum levels of adiponectin and overnight spent dialysate levels of cancer antigen 125, adiponectin, and interleukin 6 (IL-6). No differences between the 2 groups were observed for serum C-reactive protein and IL-6 levels.
Limitations:
Unblinded, relatively short follow-up; no formal sample-size calculations.
Conclusions:
Use of a combination of 3 biocompatible PD fluids for 12 months compared with conventional PD fluid did not affect RRF, but was associated with better preservation of daily urine volume. The biocompatible PD fluids also lead to changes in small-solute transport and an increase in dialysate cancer antigen 125, IL-6, adiponectin, and systemic adiponectin levels, but have no effect on systemic inflammatory response. The clinical significance of these changes, while of great interest, remains to be determined by further studies.
Related Concept Videos
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Peritoneal Dialysis I: Introduction and Procedure
Peritoneal Dialysis III: Nursing Management
Acute Kidney Injury V: Interprofessional Care
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy