Related Experiment Video
Updated: May 20, 2026

Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films
Published on: November 9, 2015
Evaluation of a titanium dioxide-based DGT technique for measuring inorganic uranium species in fresh and marine
Colin M Hutchins1, Jared G Panther, Peter R Teasdale
1Environmental Futures Centre, Griffith University, Gold Coast Campus, Queensland 4222, Australia.
Abstract:
A new diffusive gradients in a thin film (DGT) technique for measuring dissolved uranium (U) in freshwater is reported. The new method utilises a previously described binding phase, Metsorb (a titanium dioxide based adsorbent). This binding phase was evaluated and compared to the well-established Chelex-DGT method. Batch experiments showed quantitative uptake (100±3%) of dissolved U by Metsorb and an elution efficiency of 95% was obtained using a mixed eluent of 1 mol L(-1) NaOH/1 mol L(-1) H(2)O(2). The mass of U accumulated by Metsorb was linear (R(2)≥0.98) with time across the pH range 3.0-8.1, validating the DGT measurement. The measured effective diffusion coefficients were highly dependent on pH, ranging from 2.74-4.81×10(-6)cm(2)s(-1), which were in reasonable agreement with values from the literature. Ionic strength showed no effect on the uptake of U, and thereby on diffusion coefficients, at NaNO(3) concentrations ≤0.01 mol L(-1), but caused the U concentration to be underestimated by 18% and 24% at 0.1 mol L(-1) NaNO(3) and 0.7 mol L(-1) NaNO(3), respectively. Deployment of Metsorb-DGT in synthetic freshwater resulted in reliable measurement of the dissolved U concentration (C(DGT)/C(Sol)=1.05), whereas Chelex-DGT significantly underestimated the dissolved U concentration (C(DGT)/C(Sol)=0.76). Metsorb-DGT was found to give reliable results after 8h deployments in synthetic seawater but experienced competition effects with longer deployments. The Chelex-DGT was unable to measure U at all in synthetic seawater. A field deployment in a freshwater stream (Coomera River) confirmed the utility of the Metsorb-DGT method for measuring U in natural freshwaters, but performance of field deployments may require further evaluation due to the possibility of major changes in uranium speciation with pH and water composition. We recommend a filtered sample, of any water in which DGT measurements are to be made, be used to determine the appropriate diffusion coefficient under controlled laboratory conditions.
Related Concept Videos
Microbial Bioremediation of Uranium
EDTA: Indirect and Alkalimetric Titration
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...

