Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Stokes' Law01:20

Stokes' Law

Viscous forces, like friction, are intermolecular forces that resist the relative motion of molecules over each other. When a solid body moves through a liquid, viscous forces drag it in the opposite direction. The force's magnitude depends on the solid's shape and size, as well as its speed and the liquid's coefficient of viscosity, density and temperature.
The expression for the force on a solid spherical object in a fluid is called Stokes' law. Stokes' law is valid only for low Reynolds...
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Spectrophotometry: Introduction01:16

Spectrophotometry: Introduction

Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration01:16

IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration

A covalently bonded heteronuclear diatomic molecule can be modeled as two vibrating masses connected by a spring. The vibrational frequency of the bond can be expressed using an equation derived from Hooke's law, which describes how the force applied to stretch or compress a spring is proportional to the displacement of the spring. In this case, the atoms behave like masses, and the bond acts like a spring.
According to Hooke's law, the vibrational frequency is directly proportional to the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Detecting Fundamental Chiral Biosignatures in the Ultraviolet Polarization Spectrum.

Astrobiology·2026
Same author

Acute Compartment Syndrome Following a Low-Energy Ankle Injury: Case Report and Review of the Literature.

Cureus·2026
Same author

Public Health.

Alzheimer's & dementia : the journal of the Alzheimer's Association·2025
Same author

Polarization resolved hyperspectral imaging of the beetle <i>Protaetia speciosa jousselini</i>.

Optics express·2025
Same author

Linearizing the vertical scale of an interferometric microscope and its effect on step-height measurement.

Surface topography : metrology and properties·2024
Same author

Modeling the polarized X-ray scattering from periodic nanostructures with molecular anisotropy.

Journal of applied crystallography·2024
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: May 19, 2026

Imaging Intermediate Filaments and Microtubules with 2-dimensional Direct Stochastic Optical Reconstruction Microscopy
14:23

Imaging Intermediate Filaments and Microtubules with 2-dimensional Direct Stochastic Optical Reconstruction Microscopy

Published on: March 6, 2018

Compact and robust method for full Stokes spectropolarimetry.

William Sparks1, Thomas A Germer, John W MacKenty

  • 1Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, Maryland 21218, USA. sparks@stsci.edu

Applied Optics
|August 4, 2012
PubMed
Summary
This summary is machine-generated.

This study introduces a novel channeled spectropolarimetry technique. It captures full polarization data in a single 2D frame without moving parts, enabling high-sensitivity measurements across various wavelengths.

More Related Videos

Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy
09:57

Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy

Published on: July 25, 2022

Related Experiment Videos

Last Updated: May 19, 2026

Imaging Intermediate Filaments and Microtubules with 2-dimensional Direct Stochastic Optical Reconstruction Microscopy
14:23

Imaging Intermediate Filaments and Microtubules with 2-dimensional Direct Stochastic Optical Reconstruction Microscopy

Published on: March 6, 2018

Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy
09:57

Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy

Published on: July 25, 2022

Area of Science:

  • Optical Physics
  • Astronomy Instrumentation
  • Spectroscopy

Background:

  • Traditional spectropolarimetry often requires moving parts or time-dependent modulation, limiting its application for transient sources or dynamic environments.
  • Acquiring full Stokes polarization parameters typically involves multiple measurements or complex setups.

Purpose of the Study:

  • To develop a novel spectropolarimetry approach that eliminates the need for moving parts and temporal modulation.
  • To achieve high sensitivity and capture complete polarization information in a single 2D data frame.

Main Methods:

  • The technique employs channeled polarimetry, encoding polarization information along the spatial dimension of a 2D array.
  • Static, robust optical components are utilized to achieve this encoding.
  • The method is applicable across optical, UV, and IR wavelengths.

Main Results:

  • A single 2D data frame contains full spectropolarimetric information.
  • The system can be configured to measure two or all four Stokes polarization parameters.
  • The approach simplifies polarimetry for transient sources and in scenarios with relative motion.

Conclusions:

  • This static, single-frame spectropolarimetry method offers high sensitivity and robustness.
  • Its wide wavelength applicability and simplified data acquisition make it suitable for challenging environments, including space-based applications.