Urinary Bladder Distention Evoked Visceromotor Responses as a Model for Bladder Pain in Mice
Published on: April 27, 2014
Microwave Radiometry for Non-Invasive Detection of Vesicoureteral Reflux (VUR) Following Bladder Warming
Paul R Stauffer1, Paolo F Maccarini, Kavitha Arunachalam
1Radiation Oncology Department, Duke University, Durham NC, 27710.
Abstract:
BACKGROUND: Vesicoureteral reflux (VUR) is a serious health problem leading to renal scarring in children. Current VUR detection involves traumatic x-ray imaging of kidneys following injection of contrast agent into bladder via invasive Foley catheter. We present an alternative non-invasive approach for detecting VUR by radiometric monitoring of kidney temperature while gently warming the bladder. METHODS: We report the design and testing of: i) 915MHz square slot antenna array for heating bladder, ii) EMI-shielded log spiral microstrip receive antenna, iii) high-sensitivity 1.375GHz total power radiometer, iv) power modulation approach to increase urine temperature relative to overlying perfused tissues, and v) invivo porcine experiments characterizing bladder heating and radiometric temperature of aaline filled 30mL balloon "kidney" implanted 3-4cm deep in thorax and varied 2-6°C from core temperature. RESULTS: SAR distributions are presented for two novel antennas designed to heat bladder and monitor deep kidney temperatures radiometrically. We demonstrate the ability to heat 180mL saline in in vivo porcine bladder to 40-44°C while maintaining overlying tissues <38°C using time-modulated square slot antennas coupled to the abdomen with room temperature water pad. Pathologic evaluations confirmed lack of acute thermal damage in pelvic tissues for up to three 20min bladder heat exposures. The radiometer clearly recorded 2-6°C changes of 30mL "kidney" targets at depth in 34°C invivo pig thorax. CONCLUSION: A 915MHz antenna array can gently warm in vivo pig bladder without toxicity while a 1.375GHz radiometer with log spiral receive antenna detects ≥2°C rise in 30mL "urine" located 3-4cm deep in thorax, demonstrating more than sufficient sensitivity to detect Grade 4-5 reflux of warmed urine for non-invasive detection of VUR.
Related Concept Videos
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies II: Ultrasonography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...