Related Experiment Video
Updated: May 19, 2026

A Test Bed to Examine Helmet Fit and Retention and Biomechanical Measures of Head and Neck Injury in Simulated Impact
Published on: September 21, 2017
Assessment of a three-point restraint system with a pre-tensioned lap belt and an inflatable, force-limited shoulder
Richard Kent1, Francisco J Lopez-Valdes, Nate J Dennis
1University of Virginia Center for Applied Biomechanics, Charlottesville, VA 22911, USA. rkent@virginia.edu
Abstract:
This study investigates the performance of a 3-point restraint system incorporating an inflatable shoulder belt with a nominal 2.5-kN load limiter and a non-inflatable lap belt with a pretensioner (the "Airbelt"). Frontal impacts with PMHS in a rear seat environment are presented and the Airbelt system is contrasted with an earlier 3-point system with inflatable lap and shoulder belts but no load-limiter or pretensioners, which was evaluated with human volunteers in the 1970s but not fully reported in the open literature (the "Inflataband"). Key differences between the systems include downward pelvic motion and torso recline with the Inflataband, while the pelvis moved almost horizontally and the torso pitched forward with the Airbelt. One result of these kinematic differences was an overall more biomechanically favorable restraint loading but greater maximum forward head excursion with the Airbelt. The Airbelt is shown to generate generally lower head, neck, and thoracic injury metrics and PMHS trauma than other, non-inflatable rear-seat restraint concepts (viz., a standard 3-point belt and a pre-tensioned shoulder belt with a progressive load limiter). Further study is needed to evaluate the Airbelt system for different size occupants (e.g., children), non-frontal impact vectors, and for out-of-position occupants and to allow the results with this particular system to be generalized to a broader range of Airbelt designs.
More Related Videos
07:12Clinical Efficacy of an Innovative Multidimensional Traction Therapy in Moderate Adolescent Idiopathic Scoliosis
Published on: February 10, 2026
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Three-Dimensional Force System
Three Force Member
For example, consider a dumpster connected to a pin support at point A and a pin attached to a hydraulic cylinder at point B.
Applications of Stress
The...
Frictional Forces on Flat Belts
Three-Dimensional Force System:Problem Solving
To solve a three-dimensional force system, first resolve each force into its respective scalar components. Do this using...
Flat Belts: Problem Solving