Viral contamination during sequential phacoemulsification surgeries in an experimental model

Roberto Pinto Coelho1, Tatiana Vannucci Garcia, Jayter Silva Paula

  • 1Cataract Service, Department of Ophthalmology and Otorhinolaryngology, Faculdade de Medicina, Universidade de São Paulo, Ribeirão Preto, Brazil. robertopintocoelho@uol.com.br

Abstract

Insights

Piry virus genetic material was detected in non-contaminated eyes after phacoemulsification surgery, indicating cross-contamination via reused surgical equipment. This highlights potential risks during sequential cataract surgeries.

Area of Science:

  • Ophthalmology
  • Virology
  • Surgical Safety

Background:

  • Phacoemulsification is a common cataract surgery technique.
  • Disposable accessories are used to minimize contamination risks.
  • The potential for viral transmission via surgical instruments requires investigation.

Purpose of the Study:

  • To assess Piry virus contamination on surgical instruments during sequential phacoemulsification procedures.
  • To determine the incidence of viral transmission to non-contaminated eyes.

Main Methods:

  • An experimental model using pigs' eyes, with alternating contamination and non-contamination.
  • Phacoemulsification performed on eyes, with exchange of most accessories between surgeries.
  • Maintenance of the hand piece and irrigation/aspiration systems between procedures.

Main Results:

  • Piry virus genetic material was found in collector bags, tips, irrigation/aspiration systems, gloves, and anterior chambers.
  • Contamination was detected in both initially contaminated and non-contaminated eyes.
  • Scalpel samples showed contamination in 3/4 contaminated eyes but 0/4 non-contaminated eyes.

Conclusions:

  • Viral genetic material was detected in non-contaminated eyes post-surgery.
  • This demonstrates Piry virus transmission during sequential surgeries.
  • Reuse of hand piece and irrigation/aspiration systems likely facilitated viral spread.