Related Experiment Video
Updated: May 19, 2026

A Test Bed to Examine Helmet Fit and Retention and Biomechanical Measures of Head and Neck Injury in Simulated Impact
Published on: September 21, 2017
Clinically relevant measures of fit? A note of caution
1Division of Preventive Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, USA.
Abstract:
Risk reclassification methods have become popular in the medical literature as a means of comparing risk prediction models. In this issue of the Journal, Pencina et al. (Am J Epidemiol. 2012;176(6):492-494) present further results for continuous measures of model discrimination and describe their characteristics in nested models with normally distributed variables. Measures include the change in the area under the receiver operating characteristic curve, the integrated discrimination improvement, and the continuous net reclassification improvement. Although theoretically interesting, these continuous measures may not be the most appropriate to assess clinical utility. The continuous net reclassification improvement, in particular, is a measure of effect rather than model improvement and can sometimes exhibit erratic behavior, as illustrated in 2 examples. Caution is needed before using this as a measure of improvement. Further, the test of the continuous net reclassification improvement and that for the integrated discrimination improvement are similar to the likelihood ratio test in nested models and may be overinterpreted. Reclassification in risk strata, while requiring thresholds, may be more relevant clinically with its ability to examine potential changes in treatment decisions.
Related Concept Videos
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast, controlled...
Goodness-of-Fit Test
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Clinically Relevant Drug Product Specifications: Methods of Establishment
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
