Related Experiment Video
Updated: May 19, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Solid-phase microextraction using octadecyl-bonded silica immobilized on the surface of a rotating disk:
Alejandro Cañas1, Pablo Richter
1Departamento de Química Inorgánica y Analítica, Facultad de Ciencias Químicas y Farmacéuticas, Universidad de Chile, Casilla 653, Santiago, Chile.
Abstract:
Solid-phase microextraction of hexachlorobenzene from water was implemented for the first time on a rotating disk coated with an octadecyl-bonded silica (C(18)) sorptive phase. The results indicate that the sorption performance of this phase for the model analyte selected is similar to that observed using a rotating disk containing PDMS. In both cases, equilibrium is achieved within approximately 120 min for samples volumes of 50 mL and decreases to 20-30 min when the sample volume is decreased to 10 mL. The comparable behavior observed for the sorption of HCB in both phases is consistent with a similar rate-determining step for extraction, which suggests that the overall mass transfer of analyte is not limited by internal diffusion into the phase but by diffusion into the aqueous stagnant layer. The main advantage in the use of the C(18) phase is that the elution of the analyte was achieved in 15 min compared with 45 min for PDMS because, in the case of C(18), dichloromethane can be used as the eluting solvent. The detection limit of the method was 0.08 μg L(-1) HCB for a tap-water sample. The mean recovery for the analyte was 84±2% and 85±3% for the C(18) and PDMS phases, respectively, which indicates good accuracy and precision of the method.
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...