Related Experiment Video
Updated: May 19, 2026

05:37
Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Influence of surgeon's experience on fluoroscopy time during endourological interventions
M Ritter1, F Siegel, P Krombach
1Department of Urology, University Hospital Mannheim, 68135, Mannheim, Germany. manuel_ritter@gmx.net
World Journal of Urology
|August 14, 2012
Summary
Informing experienced surgeons about their fluoroscopy time significantly reduces radiation exposure during simpler endourological procedures. Inexperienced surgeons showed less improvement in fluoroscopy and operation times.
Area of Science:
- Urology
- Medical Imaging
- Radiation Safety
Background:
- Fluoroscopy time is a key factor in radiation exposure for patients and surgeons during endourological procedures.
- Understanding how surgeon experience influences fluoroscopy habits is crucial for optimizing radiation safety.
Purpose of the Study:
- To evaluate changes in fluoroscopy habits among endourological surgeons after receiving feedback on their fluoroscopy times.
- To assess the impact of surgeon experience on the ability to reduce fluoroscopy and operation times.
Main Methods:
- 402 endourological interventions (ureter stent placement, ureter stent change, nephrostomy change, ureterorenoscopy, percutaneous nephrolithotomy) were analyzed.
- Surgeons were categorized by experience (>2 years vs. <2 years).
- Fluoroscopy time and operation time were recorded before and after surgeons received feedback on their performance.
Main Results:
- Surgeons reduced median fluoroscopy times by up to 55% after receiving feedback.
- Experienced surgeons significantly reduced operation and fluoroscopy times for simpler procedures (USP, USC, NC).
- No significant reduction in operation or fluoroscopy times was observed for complex procedures (URS, PCNL) or by inexperienced surgeons.
Conclusions:
- Informing experienced surgeons about their fluoroscopy time can significantly decrease radiation exposure during less complex endourological interventions.
- Inexperienced surgeons have a limited ability to modify their fluoroscopy habits even with feedback.