Related Experiment Video
Updated: May 19, 2026

Transperineal Prostate Biopsy Using a Cone-shaped Double-hole Method with Dual-plane Probe Guidance
Published on: June 6, 2025
Prostate cancer detection with real-time elastography using a bi-plane transducer: comparison with step section
Yunkai Zhu1, Yaqing Chen, Tingyue Qi
1Department of Ultrasound in Medicine, Xinhua Hospital Affiliated to Shanghai, Jiaotong University School of Medicine, 1665 Kongjiang Road, Shanghai, 200092, People's Republic of China.
Purpose:
To evaluate elastography using a bi-plane transducer for localizing prostate cancer (PCa) in patients scheduled for radical prostatectomy (RP), in comparison with step section pathological analysis.
Methods:
Fifty-six consecutive PCa patients underwent real-time elastography examination with a bi-plane transducer before RP. Transverse elastographic images were obtained from the apex to the base by slightly compressing and releasing the prostate tissue using the probe. The diagnostic performance of elastography was evaluated in correlation with step section RP histopathology.
Results:
In 56 PCa patients, gray-scale ultrasonography detected at least one lesion in 36 patients, whereas elastography detected at least one lesion in 53 patients (P = 0.001). The overall sensitivity, specificity and accuracy of elastography in depicting tumor lesions were 67.6, 89.5 and 82.7 %, respectively. The detection rate of a PCa lesion with elastography was best in the left posterior region, followed by the right posterior region. Elastography was more sensitive in detecting PCa lesions with higher Gleason scores, diameter >5 mm and extracapsular extension.
Conclusions:
The additional use of elastography with the bi-plane transducer can improve PCa detection rate by providing more information about tissue stiffness within the prostate gland.
