Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Characteristics of diffusion-weighted stimulated echo pulse sequence in human skeletal muscle
Junichi Hata1, Kazuo Yagi, Keigo Hikishima
1Department of Radiology, University of Tokyo Hospital, 7-3-1 Hongoh, Bunkyo ward, Tokyo, 113-8655 Japan. hatahata2007@yahoo.co.jp
Abstract:
The aim of our study was to simulate an effective diffusion-weighted imaging (DWI) pulse sequence and to evaluate the best b value in skeletal muscle. The evaluated pulse sequences were spin echo (SE), stimulated echo (STE), and gradient-recalled echo (GRE). The signal intensity changed in some DWI pulse sequences when the b value was changed. Moreover, the static magnetic field of 1.5 T was compared with that of 3.0 T. Next, diffusion tensor imaging of the human skeletal muscle was measured. The experimental subjects were healthy male volunteers (n = 7; age 21.8 ± 1.1 years). We changed the b value in steps of 100 s/mm(2) from 0 to 2000 s/mm(2), and the diffusion values [fractional anisotropy (FA), λ(1), λ(2), and λ(3)] were calculated based on the data. The STE method could maintain signals up to b values of 1300 s/mm(2), but the SE and GRE methods suffered from high noise. In the human study, the mean FA (±SD) was 0.41 ± 0.02 in the tibialis anterior muscle (TA) and 0.31 ± 0.02 in the soleus muscle (SOL) at a b value of 1000 s/mm(2). The correlation of the FA with the b value coefficient and the P value by Student's t test were r = 0.981 and P < 0.001 for the TA and r = 0.982, P < 0.001 for the SOL. However, the FA became high with a low b value. In conclusion, STE was very useful for DWI in a short T (2)-value tissue. Moreover, a minimum b value of 800 s/mm(2) was necessary for evaluation of human skeletal muscle.
More Related Videos
09:40Phosphorus-31 Magnetic Resonance Spectroscopy: A Tool for Measuring In Vivo Mitochondrial Oxidative Phosphorylation Capacity in Human Skeletal Muscle
Published on: January 19, 2017
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
Related Concept Videos
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Excitation-Contraction Coupling in Skeletal Muscles
When an action potential...
Magnetic Resonance Imaging