Related Experiment Video
Updated: May 19, 2026

Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study
Published on: March 14, 2017
Comparison between an accelerometer and a three-dimensional motion analysis system for the detection of movement
1Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, China.
Objective:
To examine the reliability and concurrent validity of an accelerometer compared with a three-dimensional (3D) motion analysis system for measuring the motor reaction time of the lower limbs, to validate a simple method for objective clinical assessment of movement onset.
Design:
Timing of the onset of knee extension movement in response to an audio signal was measured simultaneously with an accelerometer and a 3D VICON motion analysis system.
Participants:
Twelve able-bodied subjects with a mean age of 26 (standard deviation 2.3) years.
Results:
Good reliability was found for both instruments, although the intraclass correlation coefficient (ICC) was higher for the accelerometer (ICC₃,₁=0.739; P<0.001). The mean motor reaction time measured by the accelerometer and the VICON system was 205.0 and 196.9 mseconds, respectively. Good agreement was found between the paired measurements (mean ICC=0.774), and the average 95% limits of agreement were -56.4 to 72.5 mseconds.
Conclusion:
In conclusion, the accelerometer had good reliability for the measurement of movement onset time. Agreement between the measurements from the accelerometer and the VICON system was high. However, the limits of agreement covered a wide range, so absolute timings for movement onset derived from these methods should not be used interchangeably.
Related Concept Videos
Relative Motion Analysis - Acceleration
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the drone...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it instrumental in...
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...

