Related Experiment Video
Updated: May 19, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
CT-fluoroscopy in chest interventional radiology: sliding scale of imaging parameters based on radiation exposure
Yoshikazu Yamao1, K Yamakado, H Takaki
1Department of Radiology, Mie University Hospital, Tsu, Japan. yamao@clin.medic.mie-u.ac.jp
Aim:
To verify the usefulness of a sliding scale of imaging parameters to reduce radiation exposure during chest interventional radiology (IR), and to identify factors that increase radiation exposure in order to obtain acceptable computed tomography (CT)-fluoroscopy image quality.
Materials And Methods:
The institutional review board approved this retrospective study, for which the need for informed consent was waived. Interventional radiologists determined the optimal CT-fluoroscopy imaging parameters using the sliding scale based on the radiation exposure dose. The imaging parameters were changed from those generating low radiation (120 kV/10 mA, 1.2 mGy/s) to others generating higher radiation exposure until acceptable image quality was obtained for each procedure. Validation of the imaging parameter sliding scale was done using regression analysis. Factors that increase radiation exposure were identified using multiple regression analysis.
Results:
In 125 patients, 217 procedures were performed, of which 72 procedures (33.2%, 72/217) were performed with imaging parameters of minimum radiation exposure, but increased radiation exposure was necessary in 145 (66.8%, 145/217). Significant correlation was found between the radiation exposure dose and the percentage achievement of acceptable image quality (R(2) = 0.98). Multivariate regression analysis showed that high body weight (p < 0.0001), long device passage (p < 0.0001), and lesions above the aortic arch (p = 0.04) were significant independent factors increasing radiation exposure.
Conclusion:
Although increased radiation exposure dose might be necessary to obtain acceptable chest CT-fluoroscopy images depending on the patient, lesion, and procedure characteristics, a sliding scale of imaging parameters helps to reduce radiation exposure.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography