Epi-aortic Doppler measurement of cardiac output in univentricular connection
Ad J J C Bogers1, Martin van den Burg, Ronald Schepp
1Department of Cardiothoracic Surgery, Thoraxcentre, Erasmus University Medical Centre, Rotterdam, The Netherlands.
Background:
In the initial postoperative period after a Fontan-type operation for a univentricular circulation, cardiac output information is important, but cannot be provided by conventional methods due to the surgical reconstruction of the heart. In this regard we investigated the feasibility of epi-aortic Doppler measurements in order to calculate cardiac output.
Methods:
: Epi-aortic cardiac output measurement was compared with Fick measurements as the gold standard in eight patients with a univentricular circulation after a Fontan-type operation.
Results:
The mean diameter of the aorta by epi-aortic measurement was 18 mm (range 14 to 25), by angiography 17 mm (range 10 to 24), correlation coefficient 0.88 (p < 0.05). The mean cardiac output by epi-aortic measurement was 2.8 l.min(-1) (range 1.2 to 6.3), by the Fick calculations 1.8 l.min(-1) (range 0.8 to 5.0). The correlation coefficient for cardiac output data in aortic diameters up to 20 millimeter in diameter was 0.55 (p < 0.05).
Conclusions:
Epi-aortic Doppler measurement of cardiac output after Fontan type reconstructions could be applied in aortas up to 20 millimeter in diameter. A reasonable correlation with Fick calculations was found. This was supported by Bland-Altman plotting. The method is intrinsically invasive, but application and removal of the device were easy and no complications related to the system were observed. An important restriction is the often present abnormal anatomy, either congenitally or after surgery.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...