Related Experiment Video
Updated: May 19, 2026

A Novel Approach for the Administration of Medications and Fluids in Emergency Scenarios and Settings
Published on: November 9, 2016
Medication records in the emergency department: agreement between paper-based charts and automated dispensing device
Andrew Wing1, Barbara Hill-Taylor, Ingrid Sketris
1, BSc, is a medical student in the Faculty of Medicine, Dalhousie University, Halifax, Nova Scotia.
Background:
Research exploring the agreement between traditional medication records and electronic records generated by an automated dispensing device has been limited.
Objective:
To evaluate the extent of agreement between medication administration records written in paper-based emergency department charts and records generated by an automated dispensing device with regard to the presence or absence of a single, prespecified medication.
Methods:
Medication administration records in paper-based emergency department charts and medication dispensation records generated by an automated dispensing device were evaluated for concordance. The primary outcome measure was agreement between the 2 sources with regard to the presence or absence of a record for salbutamol by metered-dose inhaler (MDI) for randomly selected patients who presented to a pediatric emergency department with wheeze-related illness from January 1, 2008, to December 31, 2009.
Results:
In total, 1172 patient visits met the inclusion criteria. Of these, records for 1013 visits showed agreement between the paper-based emergency department chart and the dispensation record of the automated dispensing device (kappa = 0.71, 95% confidence interval 0.67-0.75). This value did not meet the target kappa of 0.80. Stratification by time of day, day of week, month, season, or year of presentation at triage or by triage level or disposition (whether or not the patient was admitted to the hospital ward) did not significantly affect the level of agreement between the 2 sources.
Conclusions:
Agreement between records of salbutamol MDI administration in paper-based charts and dispensation records from an automated dispensing device was substantial, but discrepancies were present. There are significant quality management, legal, clinical, and research reasons to strive for concordance between multiple records with respect to medication use in the emergency department. Data generated by automated dispensing devices have potential value for research, but their strengths and limitations need to be understood.
Related Concept Videos
Methods of Documentation VII: EMR
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Methods of Documentation II: POMR
Types of Reports III: Telephone and Verbal Reports
Here's an overview of each type:
Telephone Orders
Guidelines for Nursing Documentation II
Timely documentation is crucial to ensure continuity of care for patients. Any delays in recording or reporting medical information can result in medical errors and even adverse patient outcomes. From medication administration to diagnostic test results, every detail must be accurately and promptly documented to provide the best possible care for patients.
Purpose of Health Records II